00.45
•
Switch on the ignition
L Note:
After switching on the ignition, always wait for the
BMW Integral ABS to complete its self-diagnosis.
Do not operate the brake lever until self-diagnosis
has completed.
e Attention:
The brake fluid must always be visible in the contain-
er, because the piston in the base of the wheel-cir-
cuit reservoir must always be covered by the fluid.
The procedure must be repeated if the fluid drops
below the “min” level.
•
Very gently press the footbrake lever until the
pump just starts up.
•
Open the bleed screw, while topping up the con-
tainer with new brake fluid if necessary.
•
Pump out the brake fluid with virtually no pres-
sure to begin with, then vary the brake pressure.
L Note:
The higher the brake pressure the faster the fluid is
pumped through the system, which means that the
level in the wheel-circuit reservoir drops all the more
rapidly.
•
When the brake fluid is clear and free of bubbles,
continue pumping until the fluid in the container
just disappears from view.
•
Close the bleed screw.
•
Release the brake and switch off the ignition.
•
Disconnect the brake bleeding device from the
bleed screw.
•
Disconnect the container from the wheel-circuit
reservoir.
e Attention:
After changing and/or bleeding the brakes, always
top up the fluid in the wheel-circuit reservoir to the
correct level in accordance with the instructions.
MAX
MI N
R28340090
Commenti su questo manuale